Control board for stoves, chimneys and water and air biomass boilers.
Creatio BC is the answer to control compact boilers, burners and pellet stoves.
Its flexibility allows any kind of granulated fuel (pellet, olive pit, almond shell, etc.) to be used.
Creatio BC controls the most common elements in boilers or stoves, such as combustion or suction ventilator, feed speed, security elements, resistance for automatic ignition, inertial or ACS storage tank changing without external thermostats.
Control touchscreen.
It is controlled from a 4.3" full color touchscreen for easy and intuitive operation.
Possibility to incorporate lambda probe.
To ensure compliance with increasingly demanding environmental regulations, it is posible a direct connection to Creatio LC through a lambda probe, reducing space required and costs.
The lambda probe alters the quantity of air and/or fuel that inserts in the boiler to adapt the oxygen level in fumes to the desired value.
Features
Main functionalities of the Creatio BC switchboard.
BC switchboard controls the different operating stages of the boiler or burner, considering the current boiler temperature and the fumes temperature:
- Ignition
- Stabilisation
- Standard
- Modulation
- Maintenance
- Security
- Alarm
The switchboard is equipped with a sufficiently large number of inputs and outputs to fit in with the main operational requirements.
- Inputs for probes.
- Digital inputs for external controls, boiler door opening protection, thermostats for ACS or inertia accumulators, etc.
- Outputs with TRIAC modulation or through 0-10V, allowing to control the ventilators speed, augers screws, etc.
- It also controls the relevant aspects of installation, such as pumps and inertia accumulator temperature, therefore it is not necessary a separate thermostat.
Datasheet
Technical specifications.
Power |
230/115 VAc - 50/60 Hz |
Dimensions of electronic card |
Eurocard 115 x 100 mm. |
Dimensions of touchscreen |
143 x 98 mm (external) - 138 x 93 mm (Internal for hole). |
Thermocouple probes inputs |
1 thermocouple K input for fume temperature. |
NTC probes inputs |
2 NTC10K probes inputs for boiler water temperature or generator air outlet and a second input for inertia accumulator. |
0-10V analog or digital inputs |
2 digital 0-12 V inputs for thermostat input, emergency, multifunction buttons, etc. |
Digital inputs |
2 digital inputs. |
Relay outputs |
2 230V ON/OFF outputs for auger management, pump, ignition coil. |
TRIAC outputs |
2 230V Triac outputs with phase modulation to control the speed of combustion air, fume extraction, etc. |
Extensions |
Connection for Lambda Probe. |
Type of connectors |
Connectors for crimping. |